Railway Signalling Cable – Type C, D & E – LSZH, EPR, PCP – 0.75mm to 35mm
- Description
Description
Overview
Signalling cable especially manufactured for Network Rail against their specification NR/PS/SIG/00005, formerly RT/E/PS/00005.
STANDARDS
- Conductor to BS EN 60228 (previously BS 6360)
- EPR Insulation to BS7655-3-2
- Network Rail Specification NR/PS/SIG/00005
CONSTRUCTION
Conductor: Flexible tinned or stranded copper conductor to BS EN 60228 (previously BS 6360)
Insulation: Ethylene Propylene Rubber (EPR)
Sheath:
Type C1 & C2: Heavy duty PCP RS2
Type D1 & D2: Low Smoke Zero Halogen (LSZH)
Type E1 & E2: Low Smoke Zero Halogen (LSZH)
Sheath Colour: Black
CHARACTERISTICS
Voltage Rating: 650/1100 volts
Temperature Limits: Fixed -25°C to +85°C
Minimum Bending Radius: As per cable manufacturer datasheet
Should not be installed at temperatures below 0°C or above +60°C
For more information please consult a member of the JIANYE CABLE